Your PDF is generated, give us a second ...

Compatibility Matrix Datasheet

LLS79N02

Ø 45 mm narrow beam collimator LLC79N7 + black holder

Compatibility Matrix

Measured results in black Simulated results in blue
LED Manufacturer LED Reference FWHM 1 FWHM 2 FWTM 1 FWTM 2 LOR Efficacy 1 Efficacy 2 CCI
CITIZENCLU7A310.920.090.118.33.4
CITIZENCLU72125.241.089.34.21.9
CREECXB 131014.925.889.210.72.8
CREECMB181828.749.987.23.11.1
CREECMU153231.858.982.22.20.6
LUMILEDSLUXEON_CX_PLUS_COB_S01 (GEN2)12.923.692.313.74.5
LUMINUSCXM_39.217.991.024.11.0

LLS79N02 with

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)

LLS79N02 with CITIZEN CLU7A3

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
10.920.018.3
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/CITIZEN/CITIZEN.jpeg
CITIZENCLU7A3
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)
Accessories
LLS79N00LLH66B102LLH66B100

LLS79N02 with CITIZEN CLU721

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
25.241.04.2
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/CITIZEN/CITIZEN.jpeg
CITIZENCLU721
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)
Accessories
LLS79N00

LLS79N02 with CREE CXB 1310

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
14.925.810.7
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/CREE/CREE.jpeg
CREECXB 1310
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)
Accessories
LLS79N00LLH66B102LLH66B100

LLS79N02 with CREE CMB1818

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
28.749.93.1
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/CREE/CREE.jpeg
CREECMB1818
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)
Accessories
LLS79N00LLH66B102LLH66B100

LLS79N02 with CREE CMU1532

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
31.858.92.2
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/CREE/CREE.jpeg
CREECMU1532
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)
Accessories
LLS79N00LLH66B100LLH66B102

LLS79N02 with LUMILEDS LUXEON_CX_PLUS_COB_S01 (GEN2)

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
12.923.613.7
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/LUMILEDS/LUMILEDS.jpeg
LUMILEDSLUXEON_CX_PLUS_COB_S01 (GEN2)
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)
Accessories
LLS79N00LLH66B100LLH66B102

LLS79N02 with LUMINUS CXM_3

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
9.217.924.1
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/LUMINUS/LUMINUS.jpeg
LUMINUSCXM_3
A lengthB heightC foot
45.0(mm)
Normalized Intensity
Viewing angle (deg.)
Accessories
LLS79N00LLH66B100LLH66B102
GAGGIONE S.A.S DOCUMENTS AND DATA All data provided in our datasheets, mechanical drawing and all other downloadable documents on our website www.optic-gaggione.com  are subject to change at any time without prior notice. GAGGIONE S.A.S. do not guarantee any of its own document nowhere else than on its own websites. As a consequence, all GAGGIONE S.A.S. documents that are downloadable on distributors, partners or other third-party websites or mobile applications are NOT guaranteed by GAGGIONE S.A.S. All data provided in our documents are based on our own measurements and evaluation and performed in-house in our optical laboratory, or in a certified third-party laboratory. Also, all data, even simulated data, are provided for reference and design purpose only. All data may change at any time if GAGGIONE S.A.S. improves its products/services or improves its own laboratory equipment. GAGGIONE S.A.S. is not responsible for the final use conditions and takes no responsibility under certain use conditions, out of the material specification (PMMA, PC, Silicone, any other material used in our products). USE OF CHEMICAL AGENTS FOR CLEANING OR ANY OTHER PURPOSES GAGGIONE S.A.S. recommends only the use of an optical duster along with purified water. Any other product containing chemical agents, especially alcohol or glue, may damage the mechanical or photometrical properties of the product. This applies for direct contact with the product or nearby chemical agents vapors or drops. Always wear clean gloves not to alter the product’s optical performances. GAGGIONE S.A.S. recommends the user to test its products in both prototypes and series assembly conditions in the end-fixture.